4. Programming
Page 30 496929
X3 Double Knock (2) Zones with this attribute will cause an alarm
condition only if one or more sensors generate two alarms events
within a five minute time window, or if one zone remains open for
more than 10 seconds. Programming a zone as ‘Double Knock’ is a
way of reducing false alarms caused by environmental changes, but is
not normally recommended.
Note: ‘Double Knock’ is available only for Normal Alarm and Entry Route
zone types.
X4 Omit Allow (O) When applied to a zone, this attribute allows the user
to omit the zone.
B Level B When applied, the zone will be armed when the user selects
Level B.
C Level C When applied, the zone will be armed when the user selects
Level C.
D Level D When applied, the zone will be armed when the user selects
Level D.
X7 Sensitivity When you use this Command you must also enter an extra
digit in the range 1 to 6 in order to set the sensitivity of the shock
sensor. 1 is least sensitive, 6 is most sensitive. Note that to use this
attribute you must make one of zones 1 to 4 a shock analyser type.
To adjust the sensitivity you must enter the complete Command, for
example to change the sensitivity to 3 you must key in: X7 + 3.
20: Change Engineer Code
To change the Engineer access code:
1. Make sure you are in programming mode.
2. Key in 20 and press Y.
The display shows:
20:Code
3. Key in a new four digit Engineer access code.
The display shows:
20:Code ****
4. Press Y.