M800, M800iD Plus™, M1000 and M3000 Manager's Manual

Strona 2

8 Option 1-4: Changing your User Code This option enables you to change your own user code. To make changes for other users, refer to page 19. User

Strona 3 - Contents

9 Option 1-5: Enabling Chimes This option enables you to select which of your wards (if any) use the chime feature. In a ward with this feature

Strona 4 - Introduction

10 Option 1-6: Setting the Speaker Volume This option enables you to adjust the volume level of the extension loudspeaker connected to the control

Strona 5 - Accessing the User Menus

11 Option 1-7: Customising Text This option enables you to edit the following text strings: Banner TextBanner TextBanner TextBanner Text Thi

Strona 6 - Options in User Menu 1

12 Option 1-8: Setting Up Silent Set Wards This option enables you to select which of your wards (if any) set silently, without emitting an exit to

Strona 7

13 Option 1-9: Configuring Engineer Access This option enables you to define a period during which an engineer can log into the alarm system. On

Strona 8 - Option 1-2: Omitting Zones

14 Option 1-0: Accessing the Set/Unset Menu The set/unset menu is displayed whenever you enter your user code or present your proximity tag. This o

Strona 9

15 Options in User Menu 2 Option 2-1: Viewing Zones This option enables you to view the status of each zone, which may be: HealthyHealthyHealth

Strona 10 - Enter new code

16 Option 2-2: Setting the Time and Date This option enables you to set the system time and date. The system automatically advances/retards the

Strona 11 - Option 1-5: Enabling Chimes

17 Option 2-3: Setting Up Shunt Groups Shunt groups provide a simple way to isolate zones until further notice. Each shunt group can contain up

Strona 12 - Volume Control

© Cooper Security Limited 2005 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Coop

Strona 13 - Option 1-7: Customising Text

18 You can view any of the eight possible zones assigned to the group by using | or ¬, or pressing the hot key (1 to 8). Group 01 Zone >1Zone

Strona 14 - 8 when the display shows

19 Option 2-4: Setting Up User Codes This option allows you to define users to operate the alarm system. When setting up a user, you need to spe

Strona 15 - User 1 Menu 9

20 They can set and unset assigned wards from any keypad. Standard WardStandard WardStandard WardStandard Ward Users of this type have access to U

Strona 16

21 the user to appear to operate the alarm system normally if being coerced. To set up a Duress code, the Duress Allow setting in Engineer opti

Strona 17 - Option 2-1: Viewing Zones

22 User Codes 1Code2. Press [ to select CodeCodeCodeCode. Define new usersUser no. 053. The lowest available user number is displayed. You can press

Strona 18

23 User 05 wardsWard > 1*...6. Use the numeric keys to select the wards you want the user to have access to, then press [. Any ward numbers

Strona 19

24 Option 2-4-2: Defining User Names This option enables you to specify a name for each user. When viewing the event log (page 31), pressing r toggle

Strona 20 - Zone >

25 [. Pressing 0 to 9 selects (option number displayed) and deselects (“*” displayed) options. The options are: 0 = Set/Unset Menu 1 = Test Menu 2

Strona 21

26 Option 2-5: Setting Up Chime Zones This option enables you to select which zones generate a chime if activated when unset, or to switch chimes o

Strona 22

27 Option 2-6: Using Communications Option 2-6-1: Starting a Call Back You can use this option to initiate a connection over the telephone line to

Strona 23 - Edit Codes

1 Contents PrefacePrefacePrefacePreface...

Strona 24

28 Option 2-6-2: Editing the Call-Back Numbers This option allows you to define or edit up to four telephone numbers for communication with a PC runn

Strona 25

29 Option 2-7: Assigning Zones to Wards The assignment of zones to wards is usually carried out by your alarm company. Change these assignments

Strona 26

30 Option 2-8: Setting Up Ward Groups This option enables you to allocate wards to groups, which you can then set or unset with a single operation

Strona 27 - > 0123456789

31 Option 2-9: Using the Log Option 2-9-1: Viewing the Log This option enables you view the contents of the system log. The log contains the date

Strona 28

32 Option 2-9-2: Printing the Log If a printer is connected to the control unit, you can print some or all of the events recorded in the log. User 2

Strona 29

33 Option 2-9-3: Running a System Print For engineer use only. Option 2-9-4: Viewing the Access Log You can use this option to view the content o

Strona 30

34 Option 2-0: Setting Up Timers Option 2-0-1: Setting Up Time Switches This option enables you to define up to three time switches, which can be use

Strona 31

35 You can manually override a time switch by pressing 0, then pressing r to toggle its current status. Time Switch 1On (1) >00:005. You wi

Strona 32

36 Keypad sounders operate one minute before a ward auto-sets. Entering a user code defers setting for the period specified by the Defer Setting o

Strona 33 - Option 2-9: Using the Log

37 Enter the time in 24-hour format, (e.g. 2100 for 9:00pm), then press [. Continue from step 7. 1 Operates On :-> ...6. You will

Strona 34

2 Preface Introduction About your Alarm System Your intruder alarm system uses state-of-the-art electronics to provide comprehensive and flexible p

Strona 35

38 If a user enters his/her user code while the code-lock timer is on, the display shows "Sorry. Your code is locked out". User 2 Menu 0T

Strona 36

39 Codelock Group 1On (1) >00:005. You will see a screen similar to the one shown opposite if you have chosen to edit an on/off time. The numb

Strona 37 - >

40 Text Keys The following table shows how to obtain characters when entering text at the keypad, For example, press 2 twice to obtain the "b&

Strona 38

41 Zone Numbering Each zone has a unique 4-digit number. The meaning of the number is as follows: For all zones except those For all zones excep

Strona 39 - Ward > **

42 Log Events Event Description —- NO EVENT —- No event #### ACTIVATED Monitored zone activated #,## LEC LOST Network #, device No. ## is a LEC

Strona 40

43 ALARM #### Alarm from zone number #### ALARM WARDS:- Alarm in wards AUTOSET # OFF Autoset timer off AUTOSET # ON Autoset timer on AUXILIARY

Strona 41

44 ENGINEER ARRIVES Engineer is logged on the system ENGINEER DEPARTS Engineer is logged off the system ENTRY #### Entry mode started from zone n

Strona 42 - Text Keys

45 PASSCODE ### User number ### entered their code PAYMENT EXPIRED System payment timer has expired PC CONNECTED PC connected to control unit (

Strona 43 - Zone Numbering

46 System Records General System Details WardsWardsWardsWards 1 2 3 4 5 6 7 8 Entry Time Exit Time Set

Strona 44 - Log Events

47 Ward Groups Group Name Wards Group Name Wards 1 6 2 7 3 8 4 9 5 0 Shunt Groups Group Zone 1 Zone 2 Zone 3 Zone 4

Strona 45

3 Accessing the User Menus To access the user menus: BANNER TEXT17:30 Sun 01 JAN1. Enter your user code or present your proximity tag. 0=Set Se

Strona 46

48 Auto-Set Timer 1 Timer Set at Unset at Mon Tue Wed Thu Fri Sat Sun 1 2 3 Set Wards: Auto-Set Timer 2 T

Strona 47

49 User Details No. Name Type Wards Auto-set Auto-Unset1 Manager

Strona 48 - General System Details

50 Zone Details Zone No. Location Chime Y/N Wards

Strona 49

51 Service Record Date Engineer Action

Strona 50

52 Installer Information Installation Engineer: Installation Company: Address: Telephone Number: Reset Message: Alarm Receiving Centre

Strona 51 - User Details

53 Quick Reference BANNER TEXT17:30 Sun 01 JAN1. At the keypad, enter your user code or present your proximity tag. 0=Set Selection[Ent]=User Le

Strona 53 - Service Record

4 Options in User Menu 1 Option 1-1: Performing Bell and Walk Tests Option 1-1-1: Testing the Bell This option enables you to test the internal soun

Strona 54 - Installer Information

5 Option 1-1-2: Performing a Walk Test This option enables you to check that zones are operating correctly. You can test only those wards that you

Strona 55 - Quick Reference

6 Option 1-2: Omitting Zones Sometimes you may need to omit zones when you set your wards, e.g. if a zone is to remain occupied while the rest of t

Strona 56 - 497062 Issue 2

7 Option 1-3: Shunting 24hr Zones This option enables you to shunt (disable) all zones in selected wards that have been set up as shuntable in E

Komentarze do niniejszej Instrukcji

Brak uwag

Pertronix Dougs Headers D6672 manuels

Manuels d'utilisation et guides de l'utilisateur pour Pour la voiture Pertronix Dougs Headers D6672.
Nous fournissons des manuels en pdf 1 Pertronix Dougs Headers D6672 à télécharger gratuitement par type de document : Manuel de l'utilisateur






Plus de produits et de manuels pour Pour la voiture Pertronix

Modèles Type de document
Dougs Headers D6677 Manuel de l'utilisateur   PerTronix Dougs Headers D6677 User Manual, 3 pages
Dougs Headers D6681 Manuel de l'utilisateur   PerTronix Dougs Headers D6681 User Manual, 4 pages
Dougs Headers D6679 Manuel de l'utilisateur   PerTronix Dougs Headers D6679 User Manual, 5 pages
Dougs Headers D6682 Manuel de l'utilisateur   PerTronix Dougs Headers D6682 User Manual, 3 pages
Dougs Headers D6680 Manuel de l'utilisateur   PerTronix Dougs Headers D6680 User Manual, 5 pages
Dougs Headers D6683 Manuel de l'utilisateur   PerTronix Dougs Headers D6683 User Manual, 3 pages
Dougs Headers D900 Manuel de l'utilisateur   PerTronix Dougs Headers D900 User Manual, 2 pages
Dougs Headers D743 Manuel de l'utilisateur   PerTronix Dougs Headers D743 User Manual, 3 pages
Dougs Headers D741 Manuel de l'utilisateur   PerTronix Dougs Headers D741 User Manual, 4 pages
Dougs Headers D901 Manuel de l'utilisateur   PerTronix Dougs Headers D901 User Manual, 2 pages
Dougs Headers D920 Manuel de l'utilisateur   PerTronix Dougs Headers D920 User Manual, 2 pages
Dougs Headers D921 Manuel de l'utilisateur   PerTronix Dougs Headers D921 User Manual, 2 pages
Dougs Headers D924 Manuel de l'utilisateur   PerTronix Dougs Headers D924 User Manual, 2 pages
Dougs Headers D923 Manuel de l'utilisateur   PerTronix Dougs Headers D923 User Manual [de] , 2 pages
Dougs Headers DEC300A Manuel de l'utilisateur   PerTronix Dougs Headers DEC300A User Manual, 1 pages
Dougs Headers D926 Manuel de l'utilisateur   PerTronix Dougs Headers D926 User Manual [de] , 2 pages
Dougs Headers D925 Manuel de l'utilisateur   PerTronix Dougs Headers D925 User Manual, 2 pages
Dougs General Headers Manuel de l'utilisateur   PerTronix Dougs General Headers User Manual [de] , 2 pages
Dougs Tight Tuck Headers Manuel de l'utilisateur   PerTronix Dougs Tight Tuck Headers User Manual [de] , 2 pages