Programming - Programming Commands 9651
Page 46 11772232
41: Bell Delay
When an alarm occurs (for example, an intruder violates a zone), the system
waits for the Bell Delay before operating the external sounder for the Bell
Duration. This command sets the Bell Delay.
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 73) requires
that the Bell Delay does not exceed 10 minutes and that it is not used for
entry alarms.
Option
0 No delay (default)
1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes
6 20 minutes
42: Bell Duration
When an alarm occurs (for example, an intruder violates a zone), the system
waits for the Bell Delay before operating the external sounder for the Bell
Duration. This command sets the Bell Duration.
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 73) requires
that the Bell Duration does not exceed 15 minutes.
Option
1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes (default)
6 20 minutes
44: Level A Exit Time
This command lets you set the Exit Time for Full Set.
Option
1 10 seconds
2 20 seconds (default)
Przeglądanie stron 49