9651 Programming Commands Quick Reference
11772232 Page 77
Command Key in:
82 Output 2 Type (page 54)
82ynny
nn = See Command 81 for a list of options.
Default is 08 Strobe
83 Output 3 Type (page 54)
83ynny
nn = See Command 81 for a list of options.
Default is 03 Set Latch
85 Burg Communication Rearm
(page 56)
85yny
n =
0 Latched
1 Rearm
87 Keypad Dual Key Alarms (page 57)
87ynynyny
n =
0 Off
1 On (PA enabled)
0 Off
1 On (Fire enabled)
0 Off
1 On (Medical enabled)
Note: Setting PA to option 1 also
enables a PA from keyswitches.
88 Do not use.
90 Event Log (page 68)
90yny
Shows the most recent event in the log
n = 1 View earlier events
3 View later events
4 First event
6 Last event
X Cancel viewing
y Toggles time/date display
91 Test Normal Outputs 1 to 3 (page 71)
91y
Keys 1 to 3 operate output s 1 to 3,
press X or y to end test
92 Test Plug-by Outputs 1 to 8 (page 71)
92y
Keys 1 to 8 operate outputs 1 to 8,
press X or y to end test
94 Test Internal Sounder (page 71)
94y
Internal sounders operate, press X or y
to end test
95 Test Keypad Sounder (page 71)
95y
Keypad sounders operate, press X or y
to end test
97 Engineer Walk Test (page 71)
97y
Zn indication and Chime operate when
circuit open
X End Walk Test
98 Load Full Defaults (page 57)
98y1yny
99 Leave Installer Mode (page 57)
99yy
Command Key in:
C101-158 are for programming communications.
106 Line Fault Response (page 57)
106yny
n = 0 (Not used)
1 Audible
2 Silent
126 Select Language (page 58)
126ynny
nn =
0 = English
1 = Italian
2 = Espanol
3 = Port
4 = Nederl
5 = Francai
6 = Deutsch
7 = Norsk
8 = Svenska
9 = Dansk
X1 = Suomi
134 AC Fail User/Installer Reset (page 58)
134yny
n = 0 No Reset Required
1 User Reset
2 Installer Reset
135 Line Fault User/Installer Reset
(page 59)
135yny
n = 0 No Reset Required
1 User Reset
2 Installer Reset
136 Anti-Mask User/Installer Reset
(page 59)
136yny
n = 0 User Reset
1 Installer Reset
137 AC Fail Override (page 59)
137yny
n =
0 Never
1 Inactive
2 Any
138 Line Fault Override (page 59)
138yny
n =
0 Never
1 If Only 1 Fault
2 Any
139 Fault User/Installer Reset (page 60)
139yny
n = 0 User Reset
1 Installer Reset
140 Fault Override (page 60)
140yny
n = 0 Never
1 Inactive
141 Alert Tone On/Off (page 61)
141yny
n =
0 Off
1 On
Komentarze do niniejszej Instrukcji