Cooper Security i-on 16 Instrukcja Instalacji Strona 12

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 11
Page 12 of 16
3. Select “Installers Menu” and enter the default installer code “111111” and
press “OK”.
Note: On the IRIS Touch welcome screen you have some letters and
GSM signal Stength shown on the top line, these are indications of the
following:
E = Ethernet Synchronisation.
S = Serial communication (RS232).
Poll = Communication (polling) to the monitoring Centre.
Ѱ = Shows you have GSM registration and Signal Strength.
8. Select the “Testoption from the Installation Menu.
9. The IRIS Touch will now go check the physical Ethernet is plugged in.
If this reports back disconnected then please check the cable and connections
at both ends.
10. The IRIS Touch will now check a valid IP address has been entered.
If “IP address OK” then press “continue”, if not then please confirm the IP
settings within the panel.
Przeglądanie stron 11
1 2 ... 7 8 9 10 11 12 13 14 15 16

Komentarze do niniejszej Instrukcji

Brak uwag