Programming Reference - System Options 7510r
Page 44
Jamming Detection
The control unit can detect interfering (or "jamming")
radio signals. To enable jamming detection select
System
Options, Jamming.
If the control unit detects jamming once you have
enabled this option then the display shows an Alert
message for the user.
Batt Load Test
A battery load test is an extra test that the control unit
can carry out to test the health of the internal back-up
batteries.
When enabled, if mains power is present then the control
unit tests the ability of the batteries to deliver current
every 23 hours or on unsetting the system. (If the control
unit is communicating or playing/recording speech then
the control unit will delay the test until those activities
are finished.)
If mains power is absent then the control unit carries out
the test as soon as mains power is restored.
If battery load test is disabled the control unit carries out
other, less demanding, tests hourly or on exit from the
Installer Menu.
Siren in Part Set
This option allows you to prevent the siren from sounding
if there is an alarm during a part set.
Force Set
You may wish to allow the user to set the alarm system
when one or more of the detectors are not working or are
open (active).
Note: If you enable “Force Set” then the system does not
comply with EN50131.