7510r Programming Reference - Reporting
Page 61
control unit to make a static test call at 6:00pm every
day.
To make test calls on one day every month select
Reporting, Alarms, Static Test Call, Monthly. From the display
select a number between 1 and 31 to specify the day of
the month on which the call should take place. The
control unit will make a test call at 1am on the selected
day.
Note that the control unit will add or subtract up to 16
minutes at random to the time you specified. This is to
make sure that the ARC is not overwhelmed with a flood
of test calls from systems that have all been given the
same time.
Select
Reporting, Alarms, Static Test Call, Disabled
to disable
static test calls.
Burg Comms Rearm
This menu option determines what the control unit does
with the “Burg” Fast Format channel 3 at the end of the
siren run time. There are two options:
Disabled
The channel stays active until an Installer or user
resets the system.
Enabled
The system rearms Channel 3 once the siren timer
has expired. Once the Channel is rearmed, the
system is ready to report any new alarm. The system
bypasses any detectors that are still violated.
Notes:
If a Final Exit Zone is triggered, Channel 3 becomes
active at the end of the Programmed Entry time.
Send Tamper as Burg
When using SIA reporting this option allows you to
program the control unit to send tampers as burglary
alarms.
If you select Disabled, (the default) then the control unit
sends all SIA messages as specified in
Reporting, Alarms,
SIA Report Mode
.