7510r Programming Reference - Reporting
Page 63
Function SCANCOM SCAN
FAST
TUN
STALL
Talk DTMF ‘2’ N/A DTMF ‘C’
Listen DTMF ‘1’ N/A DTMF ‘*’
Toggle DTMF ‘*’ N/A N/A
End this call DTMF ‘5’ N/A DTMF‘#’
Play ‘Home’
message.
DTMF ‘3’ N/A N/A
2. The control unit sends the “Home” speech message
(see “Speech Dialler” on page 65) to identify the
caller.
Note that you will have to use the Speech Dialler
menu to record the Home Message.
3. The control unit sends an SMS message (see SMS
Reporting).
Call Mode
To choose the call mode for social care reporting select
Reporting, Social Care, Call Mode. The modes available are:
Disabled.
The control unit does not report any social care
alarms.
Single.
The control unit reports to the first telephone number
in the Phone Book, using a single account number
(see “Account Numbers” on page 64).
Operation: The control unit dials the number and
attempts to connect with the ARC. If the call fails, the
control unit ends the call and then re-attempts to
connect up to a maximum of 15 times.