i-on160 Basic Programming Procedures
Page 11
Defaulting Access Codes
If the User and/or Installer codes are lost then you can set the installer and
Master User codes to their default and delete all the other users, including their
tags, remote controls and PAs.
1. If possible, enter the Installer menu.
INSTALLER MENU
Detectors/Devices >
Note: If you cannot enter Installer Menu then the
control unit will start a tamper alarm when you
open its lid.
2. Remove mains power, then open the control
unit and disconnect all batteries.
Note: This procedure will not work if the control
unit lid tamper remains closed.
3. Identify the Reset Codes pins on the main PCB
(see i-on160EX Installation Guide).
4. Short the Reset Codes pins together using a
small screwdriver or jumper link. (Keep the
short on until step 6.)
5. Apply mains power.
The control unit loads the factory default
access codes:
Grade 2: User 01=1234, Installer=7890.
Grade 3: User 01=123456, Installer=567890.
The control unit starts a tamper alarm. After a
pause of several seconds (during which the
keypad display shows first the software
revision of the keypad and then the words
“Please wait...”) the keypad display shows the
time and date.
The red LEDs glow to show an alert that the
control unit lid is open.
6. Remove the short from the Reset pins.
7. Reconnect the batteries.
8. Close the control unit lid (to restore the
tamper switch).
The display shows the time and date, for
example:
I-ON160EX
00:00 01/11/2010
9. Key in the default User 01 code to silence the
sounders.
The display shows:
Call Installer
Panel lid open