The Installer Menu i-on160
Page 26
Part Set B
Name
Part Set B”
Exit Mode
Instant Set
Settle time
Appears only if Exit Mode is
Final Door”.
Exit time
40s This setting is required in
order to comply with
EN50131.
Appears only if Exit Mode is
Timed Exit” or “Silent Set”.
Entry time
45s The maximum time permitted
by EN50131-1 Clause 8.3 is 45
seconds.
Alarm Response
Internal+Siren
Part Set Final Exit
Final exit
Part Set Entry Route
Entry Route
Strobe on Set
Disabled This setting is required in
order to comply with
EN50131.
Strobe on Unset
Disabled
Part C, D
(See Part Set B)
Calendar Set
None
3 PARTITIONS
Appears only in a Partitioned
system and when zones have
a type other than “Not Used”.
Partition 1
Name
Partition 1”
Exit Mode
Timed Set
Settle Time
Appears only if Exit Mode is
Final Door”.
Exit Time
40 Appears only if Exit Mode is
Timed Exit” or “Silent Set”.
Entry Time
40 The maximum time permitted
by EN50131-1 Clause 8.3 is 45
seconds.
Alarm Response
Siren + Comms
Strobe on Set
On
Strobe on Unset
On
Part Set Exit Mode
Instant Set
Part Set Settle Time
Appears only if Exit Mode is
Final Door”.
Part Set Exit Time
Appears only if Exit Mode is
Timed Exit” or “Silent Set”.
Part Set Entry Time
Part Set Alarm
Response
Siren + Comms This setting is required in
order to comply with
EN50131.
Part Set Final Exit
Final exit
Part Set Entry Route
Entry Route
Part Set Strobe Set
Part Set Strobe Unset
Partition 2....20
Partition 20” All other defaults as for
Partition 1.
Full Set Link
Partitions 2-20: No
Calendar Set
None No events or partitions
Przeglądanie stron 31