i-on160 Installer Menu Options
Page 55
before the system sets. This may be needed if detectors are being set off
by air movements caused by the final door being closed. During this
period, the sounders stop and the system sets but the control unit ignores
any alarms generated by the detectors.
Enter two digits to specify a time in seconds, from 01 to 30.
Note: This option is available for Final Door Set exit mode only.
Exit Time
The exit time can take any value between 10s and 120s.
Note: If you select Final Door Set or Instant Set for the exit mode then the Exit
Time option does not appear in the menu.
Entry Time
The entry time can take any value between 10s and 120s. The entry time
you select in this option applies to Full set and all Part Sets.
Strobe on Set (Part Set Strobe Set)
When set to ON this option causes the control unit to activate any output
programmed as Strobe, plus the strobe on any 760ES wireless siren. The
outputs/strobes are active for three seconds after the system sets. Strobe
On Set applies to Full Set and all the Part Sets.
Strobe on Unset (Part Set Strobe on Set)
When set to ON this option causes the control unit to activate any output
programmed as Strobe, plus the strobe on any 760ES wireless siren. The
outputs/strobes are active for three seconds after the system unsets.
Strobe On Unset applies to Full Set and all the Part Sets.
Alarm Response/Part Set Alarm Response
You can select one of the following:
Internal: Keypads and loudspeakers.
Siren Keypads, loudspeakers and siren.
Siren + Comms Keypads, loudspeakers, siren and
communication. Note that any Siren
Delay (see page 69) applies to
“Siren+Comms”, but not “Internal” or
“Siren” alarm responses.
Part Set Final Exit As
This option controls how the system will treat Final Exit zones in a part
set.
Final Door In a Part Setting system, any Final Exit zones
with the Part Set B, C or D attributes will
continue to act as Final Exit zones during part
set.
In a Partitioned system, any Final Exit zones,
belonging to the partition, with the Part Set
attribute will continue to act as Final Exit
zones during part set.
Normal Alarm In a Part Setting System any Final Exit zones
with the Part Set B, C or D attributes will act
Przeglądanie stron 60