4. Programming
42 496792
To change: Key-in: Notes Default
Radio Zone Supervision 128 0 Full alarm (all sounders plus comms) Y
Fail Response 1 Internal, external and keypad sounder
2 Keypad sounders
3 Comms only
4 Inhibit set
Telecommand requires 129 0 Yes Y
Entry Door to Unset 1No
Extended Report Mode 131 0 Basic Y
1 Summary
2 Intermediate
3 Full
Send Tamper as Burglary 132 0 Off Y
1On
CID Report Restorals 143 0 Mode Basic
1 Mode Basic + Restore Y
Plug by Comms Output 1 151 nn
Where nn is one of the following:
00 Not Used 11 AC Fail
01 Fire (Y) 12 Tamper Alarm
02 PA 13 Open
03 Burglar 14 Close
04 Open/Close 15 Zone Omitted
05 Alarm Abort 16 Medical
06 Technical Alarm 17 Key-Box
07 Alarm Confirmation 18 Anti-Mask
08 RF Low Battery 19 Smoke Detector
09 RF Supervision Loss 20 Comms Acknowledge
10 Jamming 21 Battery Fault
Plug by Comms Output 2 152 Default 02 PA See Command 151
Plug by Comms Output 3 153 Default 03 Burglar See Command 151
Plug by Comms Output 4 154 Default 04 Open/Close See Command 151
Plug by Comms Output 5 155 Default 15 Zone OmittedSee Command 151
Plug by Comms Output 6 156 Default 05 Alarm Abort See Command 151
Plug by Comms Output 7 157 Default 07 Confirm See Command 151
Plug by Comms Output 8 158 Default 06 Technical See Command 151