4. Programming
496792 79
ACPO DD243: 2002 Compliance
Please study this section If you are installing an intruder alarm system in
England, Wales and Northern Ireland which has remote signalling, requires
the local Police Authority to issue a URN (Unique Reference Number) and
you have chosen to use “Sequential Alarm Confirmation” to comply with
DD243: 2002.
For installers in Scotland, the ACPOS Intruder Alarm Systems policy docu-
ment is now published, and it states: “confirmation technology (BS
DD243:2002 applies) is desirable for newly installed systems but is not
mandatory in terms of this policy. Police response to line cuts will be at the
discretion of individual forces”. Cooper Security Ltd. therefore recommend
that systems in Scotland are installed to comply with DD243:200, and install-
ers obtain copies of the ACPOS policy from their local Police.
Note: The installed system will only fully comply with the requirements of DD243:
2002 if it has been designed in accordance with this section.
Please use the following recommended Commands to ensure that the
installation is correctly programmed.
Recommended Programming Commands
Command 33 – System Reset = 1 = Engineer Reset. In addition various
other forms of reset can be used such as RedCARE reset or Anti-code (if the
CSID code has been programmed into the panel).
Commands 81, 82, 83, 84 – Output types. There are three new output types
that you can use to indicate the status of the system: Alarm Confirm, Set
Complete and Unset Complete.
Command 89 – Alarm Confirmation = 1 = enabled.
The following Commands can only be accessed if you have enabled
Alarm Confirmation.
Command 48 – Lockout Keypads During Entry = 1 = Yes. Use this option to
comply with section 6.4.5.
Command 160 – Confirm time = 30 (default).
Command 161 – Internal Sounder = Sounder on confirmed/unconfirmed
alarm.
Command 162 – External Sounder = Sounder on confirmed/unconfirmed
alarm.
Command 163 – Confirm After Entry = 0 = When a user starts the entry
timer then the control unit disables alarm confirmation. Use this option to
comply with sections 6.4.3, 6.4.4 and 6.4.6.