i-on30EX
Page 19
Figure 30 Fitting the ADSL01 Filter.
Note: If you remove the ADSL01 filter then
re-fit the jumpers to the outermost pairs of
pins. If you fail to re-fit the jumpers the
internal communicator will not connect to
the phone line.
Step 9. Fit a Plug-By
Communicator
The control unit can be connected to a
separate communicator or speech dialler
(for example, the Scantronic 8400, 8440,
660 or RedCare STU). Figure 31 shows the
connections provided by the
communications wiring harness. Note that
the output types shown in Figure 31 are the
Factory default types. See the i-on Range
Engineering Guide for details on how to
change the defaults.
Figure 31 Plug-By Communicator Wiring
Note: Comms O/P4 will be active when the
system is unset. This is normal.
To fit a communicator, follow the
instructions below.
Caution: Follow the instructions in the order
shown, or you may damage the
control unit and/or communicator.
1. Disconnect mains power from the
control unit, remove the case lid, and
disconnect the battery (if the system
has already been installed).
2. Make any necessary connections from
the communicator to the communication
wiring harness. The default is a 12V
positive voltage when the output is
inactive.
Refer to the next section if you are
using a dual-path communicator.
3. Plug the Communication Wiring Harness
onto the communications connector on
the main PCB.
If the system has already been installed:
4. Re-connect the battery.
5. Fit the case lid.
6. Apply mains power.
7. Test communicator operation.
Note: You will need to speak to the ARC in
order to confirm that the communicator has
worked correctly.