4. Programming
496964 Page 93
98: Load Full Defaults
Use this Command to load default values for all Commands.
1. Enter programming mode (if you are not already there).
2. Key in 98 Y at the keypad.
The display shows:
Load Default
3. Press 1 Y at the keypad.
The display shows (for example):
Mult Sys? OFF
4. Either:
Press 1 to create a partitioned system
Or press 0 to create a single system.
The display shows (for example):
Mult Sys? ON
5. Press Y.
The keypad gives a double "beep" confirmation tone and the control unit
loads the factory default values, erasing all previously programmed
values.
Note: The log is protected and cannot be erased by the Installer.
99: Leave Programming Mode
To leave programming mode:
1. Key in 99 Y at the keypad.
The display shows:
Exit Eng?
2. Press Y.
The display shows:
Checking Sys
and after a few seconds the control unit
resets itself and returns to user mode.
If any 24-hour, Fire, PA or Technical zones are active when you try to leave
programming mode, the keypad gives an error tone and displays all the faults.
Clear the faults shown on the display and press Y. Repeat steps 1 and 2 and
the control unit should leave programming mode.
100: Not used
This command is not used.