4. Programming
Page 80 496964
54: BVVO Supervision (not 9751)
If the alarm system must meet BVVO radio supervision requirements, select
option 1. In this mode:
If a detector is out of contact for more than 15 minutes, the control unit
shows a warning on the keypad display when a user tries to set the
system.
If a detector is out of contact for more than two hours, the action of the
control unit depends whether the system is set:
If set, logs "Sensor Tamper" and raises a full alarm
If unset, logs "Supervision Fail" and raises an internal alarm
If you select option 0, the control unit reports supervision failures after one
hour, as described for Command 128 on page 103.
55: Not used
This command is not used.
56: Number of Digits in Access Codes (not 9751)
The control unit can use either four-digit or six-digit access codes. Select
option 0 for four-digit access codes and option 1 for six-digit access codes.
Note: Changing code length causes the system to revert to factory defaults for
all access codes; four-digit defaults are 1234 (user) and 7890 (engineer),
six-digit defaults are 123456 (user) and 567890 (engineer).
57: Battery Load Test (not 9751)
This Command specifies whether the control unit should load test its backup
battery. If the battery fails a test, the control unit reports the failure to the
central station; it also emits a regular short tone through the keypad sounders
and shows the message "Batt Load Fail" on the keypad display.
Option
0 Do not load test the battery
1 Load test the battery when the system is unset or 23 hours after the
last battery test (whichever comes first).
58: BVVO Tamper Reset (not 9751)
To require an engineer to reset a tamper indication while the system is unset,
select option 1. To permit a user to reset a tamper indication in this situation,
select option 0. Irrespective of this setting, the user can continue to set and
unset the system while a tamper indication is being displayed.
Note: Use Command 38 to allow a user reset after a system tamper alarm.