4. Programming
Page 70 496964
24: Show Control Unit Account Name
An ARC can use Downloader to program an account name into the control
unit. While the control unit is in programming mode, you can display the
account name from the keypad. To do this key in 24Y. Press X to return to
programming mode.
25: Internal Sounder Delay and Duration
Option 0 of this Command makes the internal sounder use the external Bell
Delay and Duration times. Option 1 makes the internal sounder continue after
the external Bell Delay expires.
26: Internal Sounder Delay on Entry
This Command controls the time at which internal sounders operate in
response to an entry alarm.
Option 1 (the default) introduces a delay to allow silent communications when
an entry alarm is triggered; this is required by some police forces. This option
is valid only when:
Alarm Abort is Off (Command 36)
Bell Delay is not zero (Command 41)
Dual Ply is Off (Command 86)
Alarm Confirm is Off (Command 89)
If you select option 1, the control unit starts the internal sounders at the same
time as the external sounders (after any Bell Delay) if an intruder strays from
the Entry Route or the entry time expires.
If you select option 0, the control unit starts the internal sounders immediately
an intruder strays from the Entry Route or the entry time expires.
27: Exit Fault External Sounder
This command controls what happens when an exit timer completes and a
zone is still violated (for example, when a door is not shut).
Option
0 System operates the internal sounders only (default).
1 System operates both internal and external sounders.