4. Programming
496964 Page 95
103: Reporting Type
The system supports several message formats for communications:
Option
0 Scancom Fast Format (FF)
1 Contact ID (CID)
2 Scancom SIA Level I (SIAI)
3 Scancom SIA Level II (SIAII) – this does not send time and date
4 Scancom SIA Level 3 (SIA3)
5 Extended Scancom SIA Level 3 (XSIA3)
6 Home "beep" (Home)
Option 6 is not a particular message format. What it means is that the
communicator dials a number and sends a "beep" down the line. This does
not allow a complex message to be sent but means that the person answering
the call needs no special equipment to decode the message. The number of
times the communicator repeats the Home "beep" is set with Command 186.
For the 9851 only, the receiver can press "5" on the telephone keypad to
acknowledge the alarm and terminate the series of calls.
104: Not used
This command is not used.
105: Static Test Call
With static testing, the control unit makes test calls at fixed times or intervals;
alternatively, you can use Command 108 (see page 97) to set up a dynamic
test call for 24 hours after the last communication.
To disable static test calls, key in 00.
To make static test calls at a regular time, you have two options:
Ann To make a static test call at a set time every day, press A and then key in
a number between 01 and 24 to select the time for the call. For example,
key in 18 to program the control unit to make a call at 6.00pm every day.
Bnn To make a static test call on a set day of every month, press B and then
key in a number between 01 and 28 to select the day for the call. For
example, key in 22 to program the control unit to make a call on the 22
nd
day of every month. The call will be made at 1.00am on the selected day.