4. Programming
496964 Page 51
Command Key in:
66 Forbikobler Partitions –
partitioned system only (page 83)
66YnnnnY
n = A Assign keypad to Partition A
B Assign keypad to Partition B
C Assign keypad to Partition C
D Assign keypad to Partition D
Note: Each keypad can be assigned to
any or all partitions. The default is for all
keypads to belong to all partitions.
67 Forbikobler Approved (page 83)
67YnY
n = 0 Frb=Non-Appr (not approved)
1 Frb=Approved (approved)
Y
68 Forbikobler Door Timer (page 84)
68YnY
n = 0 2 seconds
1 3 seconds
2 4 seconds
3 5 seconds
Y
4 10 seconds
5 20 seconds
6 30 seconds
7 60 seconds
8 120 seconds
9 255 seconds
69 Forbikobler Door Locking (page 84)
69YnY
n = 0 Lock Timed
Y
1 Lock Toggled
70 Level/Partition C Final Exit Operation
– single system only (page 84)
70YnY
n = 0 C=FE = FE (Final Exit)
Y
1 C=FE = NA (Normal Alarm)
71 Level/Partition C Entry Route
Operation – single system only (page
85)
71YnY
n = 0 C=ER = ER (Entry Route)
Y
1 C=ER = FE (Start entry timer)
72 Level/Partition C Exit Mode (page 85)
72YnY
n = In a single system:
0 Timed low tone on setting
Y
1 Instant (no exit tone)
2 Silent (double "beep" after exit time)
3 Sets exit mode the same as Level A
In a partitioned system:
0 Timed full tone on setting
Y
1 Terminated (terminated by button)
2 Final Door (last door has a detector)
3 Instant (no exit tone)
4 Silent (double "beep" after exit time)
5 Lock Set (terminated by lock switch)
73 Level/Partition C Alarm Response
(page 86)
73YnY
n = In a single system:
0 Keypad sounders only
1 Internal and keypad sounders
Y
2 Local (all sounders, no comms)
3 Full (all sounders and comms)
In a partitioned system:
0 Keypad sounders only
1 Local (all sounders, no comms)
2 Full (all sounders and comms)
Y
Command Key in:
74 This command has been replaced by
Command 203.
75 Level/Partition C Exit Time (page 86)
75YnY
n = 1 10 seconds
2 20 seconds
Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
76 Level/Partition D Exit Mode (page 87)
76YnY
n = In a single system:
0 Timed low tone on setting
Y
1 Instant (no exit tone)
2 Silent (double "beep" after exit time)
3 Sets exit mode the same as Level A
In a partitioned system:
0 Timed full tone on setting
Y
1 Terminated (terminated by button)
2 Final Door (last door has a detector)
3 Instant (no exit tone)
4 Silent (double "beep" after exit time)
5 Lock Set (terminated by lock switch)
77 Level/Partition D Alarm Response
(page 88)
77YnY
n = In a single system:
0 Keypad sounders only
1 Internal and keypad sounders
Y
2 Local (all sounders, no comms)
3 Full (all sounders and comms)
In a partitioned system:
0 Keypad sounders only
1 Local (all sounders, no comms)
2 Full (all sounders and comms)
Y
78 This command has been replaced by
Command 204.
79 Level/Partition D Exit Time (page 88)
79YnY
n = 1 10 seconds
2 20 seconds
Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
80 Forbikobler Chime (page 89)
80YnY
n = 0 Bell push does not operate
sounders
Y
1 Bell push operates sounders