2. Programming Commands
Page 12 497096, issue 3
Value Attribute Valid for Description
X3
Double Knock
(D)
Normal Alarm
(NA)
Entry Route
(ER)
For zones with this attribute, no action is
taken on first activation. To cause an alarm,
the zone must be activated twice within a five-
minute period or remain open for longer than
10 seconds. An alarm will also occur if
another double-knock zone in any partition is
activated within five minutes of the first.
Programming a zone as "Double Knock" is a
way of reducing false alarms caused by
environmental changes but is not normally
recommended. Do not apply "Double Knock"
to radio zones with a PIR detector. The radio
PIR detector uses a lockout timer and will not
send a second activation within the Double
Knock period.
X4
Omit Allowed
(O)
All When applied to a zone, this attribute allows
the user to omit the zone when setting the
alarm. Do not allow the user to omit PA
zones.
Do not apply this attribute to an FE zone if
there is no ER zone present.
X7
The meaning of this attribute depends on the zone type:
Shock
Analyser
Sensitivity
Shock Analyser
(SA)
You can set this attribute only for a zone of
type SA, and only zones 1, 2, 3 and 4 support
this type. To set the sensitivity of a shock
sensor zone, enter a digit in the range 1 (least
sensitive) to 6 (most sensitive). You must
enter the whole sequence; for example, to set
the sensitivity to 3, press X73
Entry Timer
Number
Final Exit (FE)
Entry Route
(ER)
Forbikobler
(FB)
To select which of the four entry timers (set
up using Commands 201–4, as described on
page 66) are used for the zone, enter a digit
in the range 1 to 4. You must enter the whole
sequence; for example, to select Entry Timer
3, press X73
A Armed in
Level or
Partition A
All When applied, the zone is armed when the
user selects Level or Partition A.
B Armed in
Level or
Partition B
All When applied, the zone is armed when the
user selects Level or Partition B.
C Armed in
Level or
Partition C
All When applied, the zone is armed when the
user selects Level or Partition C.
D Armed in
Level or
Partition D
All When applied, the zone is armed when the
user selects Level or Partition D.