2. Programming Commands
Page 22 497096, issue 3
41: Bell Delay
When an alarm occurs (for example, an intruder violates a zone), the system
waits for the Bell Delay before operating the external sounder for the Bell
Duration. This command sets the Bell Delay.
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 85) requires that the
Bell Delay does not exceed 10 minutes and that it is not used for entry alarms (see
Command 26).
Option
0 No delay (default)
1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes
6 20 minutes
Note: Command 41 has no effect if Alarm Confirmation (Command 89) is enabled and any
of the following applies:
External Sounder (Command 162) is set to option 0
Internal Sounder (Command 161) is set to option 0
Alarm Response Mode (Commands 47, 63, 73 and 77) does not require
communications.
42: Bell Duration
When an alarm occurs (for example, an intruder violates a zone), the system
waits for the Bell Delay before operating the external sounder for the Bell
Duration. This command sets the Bell Duration.
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 85) requires that the
Bell Duration does not exceed 15 minutes.
Option
1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes (default)
6 20 minutes
43: Not used
Level A Entry Time has been replaced by Command 201–204.