2. Programming Commands
Page 44 497096, issue 3
106: Line Fault Response
This command sets how the control unit responds when it detects a fault on
an attached telephone line. The response depends on whether the system is
set or unset.
Option
0 Disabled. The control unit does not monitor the telephone line.
1 Audible (default).
If the system is unset, the control unit logs the event and the keypads
emit a short audible tone every minute. Entering a valid access code
silences the sounders and the keypad displays indicate a telephone
line fault. The system can be set again with the line fault present.
If the system is set, the control unit logs the event but the keypads do
not emit a tone or display a message. If the line is out of order when
an alarm occurs, the control unit cancels any programmed Bell Delay.
Note: Compliance with the NSI recommendation requires option 1.
2 Silent.
If the system is unset, the control unit logs the event and the keypad
displays indicate a telephone line fault (without giving any audible
warning). The system may be set again with the line fault present.
If the system is set, the control unit logs the event but the keypads do
not display a message. If the line is out of order when an alarm
occurs, the control unit cancels any programmed Bell Delay.
107: Not used
This command is not used.
108: Dynamic Test Call
With dynamic testing, the control unit makes a test call 24 hours after the last
communication, rather than at the fixed times or intervals specified for static
calls with Command 105 (page 43). Select option 0 (the default) to disable
dynamic test calls and option 1 to enable dynamic test calls.
Notes:
1. Cooper Security recommends that you select either Static Test Call (105) or
Dynamic Test Call (108), but not both at the same time.
2. Compliance with PD 6662 / prEN 50131-1: 2004 Grades 1 and 2 (see page 85)
requires that a test call is made within 25 hours of the last communication, which is
satisfied by Command 108. Grade 3 requires the call to be within five hours, which
is not satisfied by Command 108.
Komentarze do niniejszej Instrukcji