2. Programming Commands
Page 56 497096, issue 3
139: Fault User/Installer Reset
Use this command to determine how alerts can be reset for all faults that do
not have an individual reset command.
Option
0 User Reset (default). Fault alerts can be reset by the user or installer.
1 Installer Reset. Fault alerts can be cleared only by the installer.
Notes:
1. Resets faults including AC Fail, Aux DC, Battery Load Test Fail, Battery Missing,
Comms Fail, Jamming, Keypad Ident Fail, Line Fail, Low Battery, Plugby Fail, RF
Low Battery, Supervision Fail, Telecommand Low Battery, uCom Fail, Zone AC
Fail, Zone Battery Fault, Zone Fault, Zone Low Battery and Zone Pwr O/P.
2. Insurance policies that are conditional on compliance with PD 6662 / prEN 50131-1:
2004 (see page 85) may require that Command 139 is set to 1 to restrict the user's
ability to override alerts.
140: Fault Override
Use this command to determine how alerts can be overridden for all faults that
do not have an individual override command.
Option
0 Never (default). The user cannot override a Fault alert when setting
the system.
1 Inactive. The user can override a Fault alert when setting the system,
provided that the cause of the fault has been rectified.
Note: Overrides faults including AC Fail, Aux DC, Battery Load Test Fail, Battery Missing,
Comms Fail, Jamming, Keypad Ident Fail, Line Fail, Low Battery, Plugby Fail, RF
Low Battery, Supervision Fail, Telecommand Low Battery, uCom Fail, Zone AC
Fail, Zone Battery Fault, Zone Fault, Zone Low Battery and Zone Pwr O/P.
141 to 142: Not used
These commands are not used.