3. Testing Commands
497096, issue 3 Page 73
Keypad Display Printed (9853 only)* Meaning
U== System Reset U== Reset User – reset system
U== Time/Date U== Reset Time/Date Time and date user reset the system
U== Z== Omit U== Omitted Z== User omitted zone ==
U== Z== Unomit Zone Unomit Z== User unomitted zone ==
UserCode req off UserCode req off K== No user code before installer code
UserCode req on UserCode req on K== User code before installer code
XT ACFl Rst Z== AC Fail Rstr Zone Z== Mains power supply restored in zone ==
XT ACFl Z== AC Fail Zone Z== Mains power supply failed in zone ==
XT BatFl Rst Z== Batt Fault Rstr Zone Z== Battery reconnected in zone ==
XT BatFl Z== Batt Fault Zone Z== Battery fault in zone ==
XT Fault Z== Rst Fault Rstr Zone Z== Zone of type ‘Fault’ reset
XT Fault Zone == Fault Zone Z== Zone of type ‘Fault’ active
XT LoBat Rst Z== Low Battery Low battery reset on radio zone ==
XT LoBat Z== Low Batt Zone Z== Low battery detected on radio zone ==
XT PwrFl Rst Z== Power O/P Fault Rstr
Zone Z==
Power output fault reset in zone ==
XT PwrFl Z== Power O/P Fault Zone
Z==
Power output fault in zone ==
Note: The log is protected and cannot be erased by the Installer or a user.
91 to 96: Testing Outputs
You may test parts of the system by entering commands at the keypad. To
carry out a test make sure the system is in installer mode and then key in one
of the following commands:
91y Test normal outputs:
On 975x units, press keys 1 to 3 to toggle outputs 1 to 3 on and off.
On 9853 units, press keys 1 to 8 to toggle outputs 1 to 8 on and off.
92y Test plug-by and plug-on outputs:
Press key 0 to test the Alarm Transmission System.
On 975x units, press keys 1 to 8 to toggle outputs 1 to 8 on and off.
On 9853 units, press keys 1 to C to toggle outputs 1 to 12 on and off
(A=10, B=11 and C=12).
93y Not used.
94y Test the internal sounder output.
95y Test the keypad sounder.
96y Not used.
Press y to end each test. All outputs revert to their former settings.
Note: An Alarm Transmission System (ATS) test includes the whole communication
system, from the Alarm Transmission Equipment (ATE) attached to the control unit
to the communication equipment in use at the Alarm Receiving Centre (ARC).
Komentarze do niniejszej Instrukcji