Engineer Menu 1-9 Engineering Manual
94
)
The AC Off Delay timer (page 63) determines how long the mains must be off
before the system generates an alert.
User – An alert generated by a mains failure will require a normal user reset.
Engineer – An alert generated by a mains failure will require an engineer or remote reset.
12 – AC Bypass:Always / Healthy / Eng / Never
Always – With this option selected, an AC Mains Fault alert will not prevent a user from
being able to set the alarm system.
Healthy – Allows a user to override an AC fail alert and set the system, but only if mains is
present.
Never – Prevents the alarm system from being set if there is an AC fail alert that needs to
be reset. If the AC Fail option is set to Engineer, the system will be able to be set only after
the alert is reset by an engineer or remote reset.
13 – Line Fail:No Rst / User / Eng
No Rst – A line fault (e.g. no dial tone present) detected by the on-board modem or by an
external communicator will cause an alert to be generated, but the alert will disappear
when the line is restored. No resetting of the alert will be required.
The on-board modem can generate a "PSTN Line Fault" only if communications from the
on-board modem to an Alarm Receiving Centre (ARC) has been enabled (see page 110).
An external communicator must connect to the LINE FLT input of the panel to signal a line
fault. The line fault alert is "ATE L.F. Single" or "ATE L.F. All" (see page 49).
User – An alert generated by a line fault will require a normal user reset.
Engineer – An alert generated by a line fault will require an engineer or remote reset.
14 – LF Bypass:Always / User / Eng
Always – With this option selected, an PSTN Line Fault alert will not prevent a user from
being able to set the alarm system.
User – Allows a user to override an PSTN Line Fault alert and set the system, but only if
there is no line fault.
Eng – Prevents the alarm system from being set if there is a PSTN Line Fault alert that
needs to be reset. If the Line Fail option is set to Eng, the system will be able to be set only
after the alert is reset by an engineer or remote reset.
15 – Supervision Fail Alert
Alert – The control unit displays a supervision failure alert.
Alarm – The control unit starts an intruder alarm
TamperThe control unit starts a tamper alarm
The control unit also operates any outputs programmed as Supervision Failure.
16 – Reset Supervision Engineer/User
Reset when healthy – The control unit clears a supervision failure if none of the radio
zones allocated to the ward have a supervision failure.