Engineering Manual Engineer Menu 1-4
47
036 – Service Required
Activates when the Service Time (page 64) has expired; deactivates when the engineer
code is entered.
037 – Reset Required
Activates when the system requires an engineer or remote reset; deactivates when the
system is reset either by the engineer or by a remote reset.
038 – Strobe On Set
Activates when there is an alarm, and deactivates when the alarm is reset by the user. This
output is also active for 10 seconds after a user sets the system.
039 – Duress Alarm
Activates when a duress code is entered (as set up in User option 2-4); deactivates when
the duress alarm is reset.
040 – System Part Set
Activates when not all wards are set; deactivates when all wards are set or unset.
041 – LockSet Unlocked
Active when a Lock Set zone (page 25) is unlocked; deactivates when all Lock Set zones on
the system are locked.
042 – Set Failed
Activates when any ward fails to set (e.g. because a zone is active); deactivates when the
set fail condition is reset.
043 – Shunt Code
If the output is latched, the output activates for 2 seconds when a shunt code (as set up in
User option 2-4) is entered. If the output is pulsed, it activates for the duration of the
pulse.
044 – Random Output On
Activates randomly (between 5 and 60 minutes).
045 – Modem Lockout
Activates when the modem is locked-out (four failed attempts); deactivates when a
Manager user code is entered or after 4 hours.
046 – Aux/Bell Tamper
Activates when the bell tamper is triggered; deactivates when the alarm is reset.
047 – Panel Lid Tamper
Activates when the panel lid tamper is activated; deactivates when the alarm is reset.
048 – Chime Mimic
Activates for 2 seconds when any zone with a Chime Tone attribute (page 29) is activated,
if chimes are enabled in User option 1-5.