Compliance Guide Engineering Manual
160
ACPO PA Reduction Policy
To comply with this policy, do not enable a duress code or dual-key PA. Set E1-9-1-24 (Duress
Allow) to NO, and E1-9-1-25 (Keypad PA) to OFF.
PD 6662 / prEN 50131-1: 2004 Compliance
EN 50131-1: 2004,
Alarm systems – Intrusions and Hold-up Systems – Part 1: System
Requirements
, sets four grades for intruder alarm systems to provide levels of security required
for specific risks. M800 and M2000 control panels can be configured to fulfil the requirements
of Grades 1 to 3.
Note: This guide does not apply to EN 50131-1:1997
.
Configuring Hardware
Zones can be wired as either double-pole or FSL (fully-supervised loop), as described in the
Installation Instructions
, but FSL is recommended. To allow remote servicing, FSL should be
used.
The power available for connecting external devices to the control unit depends on the battery
used and the grade to which the system is configured. Please refer to "Power Availability" in the
Installation Instructions.
The built-in modem is suitable for signalling alarms at Grades 1 and 2. If it is used, test calls
must be made (set with E1-5-2-23/24 as described below). At Grade 3, an external
communicator is needed to provide the necessary encryption.
Programming for Compliance
Option 2-7-3-8-2 provides defaults suitable for Grade 2 or Grade 3. See page 132.