Engineer Menu 1-3 Engineering Manual
36
02 – Unconf Reset
If you select this attribute, an engineer or remote reset code must be entered to reset the
system after an unconfirmed alarm (page 89) has been sounding in the selected wards for
at least the period specified by Abort Delay (page 64). If you deselect this option, any user
whose code is assigned to the ward can reset the unconfirmed alarm. See also the Remote
Reset attribute (page 36).
03 – Tamper Reset
If you select this attribute, an engineer or remote reset code must be entered to reset the
system after a tamper alarm occurs at a zone in the selected wards while the system is
unset. If you deselect this option, any user who has access to the ward can reset the alarm.
See also the Remote Reset attribute (page 36).
04 – Remote Reset
This is relevant only if the Conf reset, Unconf Reset or Tamper Reset attribute is set (see
above). The Remote Reset attribute enables the panel to generate a code when resetting
the system after an alarm in the selected wards. The user contacts an Alarm Receiving
Centre (ARC) with the code, who (if satisfied with the caller's authority) return a one-off
remote reset code, which the user enters to reset the panel. The
User's Guide
describes
how to enter the remote reset code.
The algorithm used to generate the remote reset code is determined by the Reset Alg
option (page 65). Contact your ARC to obtain the correct algorithm number.
05 – Panel Tamper
The control panel lid tamper can be assigned to any combination of wards. If a panel
tamper occurs, keypads in the same ward will sound (see page 22), and Tamper outputs
associated with the same ward (see page 55) will activate.
See also Tampers as Alarm / Tampers as Tamps (page 91).
06 – Panel Speaker
The control panel speaker can be assigned to any combination of wards. Assigning the
speaker to the correct wards ensures that the sounders operate only when the relevant
ward(s) require a sound (e.g. for an alarm, entry or exit sound).
07 – Aux/Bell Tamp
The auxiliary and bell box tamper input can be assigned to any combination of wards. If a
bell tamper occurs, keypads in the same ward will sound (see page 22), and Tamper
outputs associated with the same ward (see page 55) will activate.
See also Tampers as Alarm / Tampers as Tamps (page 91).
08 – Payment Timer
The payment timer can be assigned to any combination of wards. When the Payment Time
(page 66) expires, the selected wards will require an engineer or remote reset (see the
User's Guide
) before the wards can be set.