Engineering Manual Engineer Menu 1-9
91
6 – Confirm 2 Zones / Confirm 1 Zone
These options are relevant only if you have selected Confirmation On and After Entry Yes.
Confirm 2 Zones (default) – A confirmed alarm is generated if the intruder activates two
additional zones after the Entry Delay timer (page 61) expires. If the control unit is in alarm
before the user starts the Entry Delay timer, only one subsequent zone violation is
required.
Select this option if you are installing a DD243:2002 para 6.4.5 compliant system
and the user must unset the system with a proximity detector (“Portable ACE”).
Confirm 1 Zone – A confirmed alarm is generated if the intruder activates one additional
zone after the Entry Delay timer (page 61) expires. This option does not comply with
DD243:2002.
Option 1-9-3: Choosing EN50131 Configuration Options
(For defaults see page 133.)
01 – 4 Digit Codes / 6 Digit Codes
4 Digit Codes – All system user (access) codes are four digits.
6 Digit Codes – All user (access) codes are six digits. When using six-digit user codes, the
default engineer code is 123400 and the default manager code is 567800.
)
You cannot change this setting if the engineer or default manager (user 01) code has been
changed, or any other user code has been set up in User option 2-4. Users can be deleted
using option 2-7-3-7 (page 131) and 2-7-3-8 (page 132).
02 – Internal Sounder / Local Sounder
Internal Sounder– If an alarm occurs while the Entry Delay timer (page 61) is running, both
the extension speaker and keypad sounders operate for 30 seconds. Once the 30-second
period has expired, a full alarm occurs (page 22), unless overridden by option 1-8-4 (page
83).
Local Sounder – Operation is the same as above, but external sounders and the strobe
also operate for the first 30 seconds.
03 – Instant Alarm / Delayed Alarm
Instant Alarm– Causes system and ward Alarm outputs (page 44 and 54) to activate
immediately a full alarm is generated by the Entry Delay timer (page 61) expiring.
Delayed Alarm – Causes system and ward Alarm outputs to be delayed by a further 30
seconds.
04 – Tampers As Alarm / Tampers As Tamps
Tampers As Alarm – If there is a tamper condition when the system is set, the control unit
will:
Communicate an alarm (CID code 130, SIA code BA) message to the Alarm Receiving
Centre (ARC). This depends on the communicator format you select if you choose to
employ the on-board modem.
Trigger system, ward and zone outputs of type "Alarm" and "Tamper Alarm" (or "Tamper").