Engineering Manual Engineer Menu 1-4
59
Zone Output Group Events
Use this option to activate an output whenever a user operates a zone output group (see pages
33 and 39 for instructions).
Step 6 – Select the Inversion and Output Mode
Output Inversion
Selecting this option inverts the sense of the output.
Output Mode
)
Output Mode is not available for certain outputs types.
The normal mode is Latched.
Selecting Pulsed causes the output always to return to its normal state after the specified
number of seconds. This can result in the output returning to the normal state sooner than if
the Latched mode is selected.