Engineering Manual Text Keys
155
The above diagram shows a typical example of a commercial building that could use the “Foyer
Mode”.
The end user requires each side of the building to be set separately, as the Office and Factory
staff will be working different hours. The control unit arms the common area (including the
Foyer and Kitchen) when there is no one in the building. This allows either the Factory or the
Office staff to use the facilities. For best operation, there should be two keypads: one fitted in
the Loading Bay and the other fitted in Reception. The keypad in the Loading Bay connects to
the control panel on Network 1. For convenience the Reception keypad connects to the
MSNode.
As this is commercial, use of Grade 3 Anti Masking detectors, each with three-resistor wiring.
See the MSNode or Panel Installer’s Guide for details.
To Program the system
Eng 1 Menu 1 – Program Zones
Zone Location Type (Hot Key) Attributes Wards Description
0001 Panel zone 1 Final Exit (7) Chime 1 (8) 1 Front Door
0002 Panel zone 2 Normal Alarm (1) Access (1) /
Masking (6)
1 Foyer PIR
0003 Panel zone 3 Normal Alarm (1) 2 Shutter
0004 Panel zone 4 Normal Alarm (1) Access (1) /
Masking (6)
2 Loading Bay PIR
0005 Panel Zone 5 Normal Alarm (1) Masking (6) 2 Factory PIR
0006 Panel zone 6 24 Hour (2) 2 Factory Fire Door
0007 Panel zone 7 Normal Alarm (1) Masking (6) 1 Kitchen PIR
1011 Keypad 1 – Zone 1 Final Exit (7) 2 Loading Bay Door
2011 MSNode 1 – Zone 1 24 Hour (2) 3 Office Fire Door
2012 MSNode 1 – Zone 2 Normal Alarm (1) 3 Office BGD
2013 MSNode 1 – Zone 3 Normal Alarm (1) Making (6) 3 Office PIR
2014 MSNode 1 – Zone 4 Normal Alarm (1) Access (1) /
Masking (6)
3 Reception PIR
2015 MSNode 1 – Zone 5 Normal Alarm (1) 3 Reception BGD
2016 MSNode 1 – Zone 6 Final Exit (7) 3 Reception Entrance
The Access attribute allows walk through when entering an entrance door
Assign Zones to wards so that areas can be set and un-set separately
Eng 1 Menu 3 – Ward Options
E1-3-1 Equipment to Wards
Device Wards
Network 1 – Keypad 1 (1,01) 12
Network 2 – MSNode 1 – Keypad 1 (2,01) 13
E1-3-2 Attributes
Attribute option Wards
06 Panel Speaker 12
12 Foyer Mode 23
Komentarze do niniejszej Instrukcji